ISO Certified | Compliant With Local Radiation Safety Policy
Powerful and Safe-to-use X-Ray Inspection System
- ISO 9001
- CE / ROHS
- X-Ray Radiation Level ≤1μSv/h
X6800 X-Ray Inspection System
X6800 is one of our most advanced real-time x-ray inspection systems, and it can be widely used in Non-destructive analysis of semiconductors, SMT, and electric component quality checking. By high-resolution imaging, engineers can easily find defects inside semiconductors, batteries, small metal casting, electronics cables and connectors, 3D Printing modules, medical devices and parts.
Features
- 40kv – 90kv closed type micro-focus closed x-ray tube(Hamamatsu), focal spot size down to 5µ
- HD digital flat panel detector (Rayence)
- 60° detector tilting for oblique angle viewing, x-ray image keep central while tilt.
- 530mm x530mm inspection area with 10kg load capacity
- Automatic navigation software provides easy positioning and identification of defects area.
- Adjustable 5 axis linkage system
- Quick inspection parameter settings, inspection area adjust.
- Inspection software provides access to create advanced inspection procedure for automated inspection in large quantities.
- Multifunctional measuring tools including BGA void detection and automatic calculations, radius, area, perimeter, measuring, repeat programming
- Industrial PC with Windows 7 PRO, 24” LCD flat panel display
- Low maintanance requirements
- 360° rotary sample jig support(optional)
- High resolution imaging
- User-friendly software interface
Specifiactions
X-ray source | Brand | Japan Hamamatsu | |
Type | Closed, microfocus | ||
Max tube voltage | 90kV | ||
Max tube current | 200μA | ||
Focal spot size | 5μm | ||
Function | Auto preheat | ||
Flat panel detector | Brand | IRAY | |
Effective area | 130mm*130mm | ||
Pixel size | 85μm | ||
Resolution | 1536*1536 | ||
Frame rate | 20fps | ||
Tiltable angle | 60° | ||
Table | Size | 530mm*530mm | |
Detectable area | 500mm*500mm | ||
Max load | 10kg | ||
Equipment | Magnification | Geometry 200X System 1500X | |
Inspection speed | Max 3.0s/point | ||
Dimensions | 1360mm (L) * 1365mm (W) * 1630mm (H) | ||
Weight | 1350kg | ||
Power supply | AC110-220V 50/60HZ | ||
Max power | 1500W | ||
Industrial PC | I5 CPU, 4G RAM, 240GB SSD | ||
Displayer | 24” HDMI LCD | ||
Safety | Radiation leakage | No leakage, international standard: ≤1μSv/h | |
Lead glass window | Transparent lead glass window shields radiation to observe the inner status. | ||
Window and back door safety interlock | Once users open the window or back door, X-ray tube will power off immediately. When the window or back door is open, users can’t turn on the X-ray. | ||
Electromagnetic safety switch | Lock once the X-ray is on, users can’t open the observation window. | ||
Emergency stop | Next to the operation position, press to power off | ||
Tube protection | User can’t leave the software to if you don’t close the X-ray tube. |
Working Principle
Application
BGA , CSP , Flip Chip, LED , Fuse, Diode, Sensors, PCB Voids Inspection
Semiconductor , Battery Industry , Small Metal Casting, Electronics Cables and Connectors, 3D Printing Module, Medical Device and Parts.
Radiation Safety Guarantee
All X-ray machines manufactured by Wellman meet the requirement of FDA-CDRH Regulation CFR 21 1020.40 Subchapter J for cabinet x-ray systems. The FDA – CDRH standard for cabinet x-ray systems states that radiation emission shall not more than. 5millirem a /hr.2″from any external surface. Our machines (X-Ray Radiation Level <1μSv/h ) are typically 5-10 times less emission than the standards, so there are no radiation concerns for operators.
Operation Safety | |
---|---|
Radiation Leakage | No leakage, international standard: ≤1μSv/h |
Lead Glass Observation Window | Transparent lead glass window to shields radiation, safe to observe the inner status. |
Window and Back Door Safety Interlock | Once open the window or back door, the X-ray tube will power off immediately. When the window or back door is open, the operator cannot turn on the X-ray. |
Electromagnetic Safety Switch | Once the X-ray is on, the window will automatically lock, so the operator can’t open the window. |