ISO Certified | Compliant With Local Radiation Safety Policy
Fast and Accurate X-Ray Component Counter System
- ISO 9001
- CE / ROHS
- X-Ray Radiation Level ≤1μSv/h
XC-01 X-Ray Reel Counter System
XC-01 is an advanced x-ray SMD reel/Component counter system, it can provide fast and accurate component counting and help to make a better inventory control, which saves your time and labor cost in component counting.
XC-01 uses advanced x-ray technology or accurate and fast counting of SMD reels. It can count multiple reels at once, saving time and increasing productivity. XC-01 can store and retrieve count data for future reference, besides it can be connected to a computer for data management and analysis.
Features
- 80kV closed type X-ray tube, longer lifetime, maintenance-free.
- 17” Super definition digital flat panel detector (FPD).
- Ultrafast counting, four 7” reels or one 15” (380mm) reel needs less than 10s.
- Support max 17” (430mm) reel or tray with a moisture barrier bag.
- Permanently updated AI deep learning algorithm for free, support connecting MES, ERP, WMS, and other management systems.
- Automatically scan codes and count at the same time, and then print the corresponding label when user takes out a reel.
- No need to switch single/multi reel mode, automatically print the label when users count one reel.
- Support work order number function and counting record query & statistics.
High Speed and High Accuracy
Reel size | Parts size | Quantity | Accuracy | Speed |
---|---|---|---|---|
7” (180mm) | 01005 | 40000 | 99.98% | 9-10s |
7” (180mm) | 02012 | 20000 | 99.99% | 8-9s |
7” (180mm) | 0402 | 10000 | 99.99% | 7-8s |
7” (180mm) | 0603 | 5000 | 99.99% | 7-8s |
10” (254mm) | 1206 | 5000 | 99.99% | 7-8s |
15” (380mm) | 1206 | 10000 | 99.99% | 7-8s |
Specifiactions
X-ray source | Type | Integrated, microfocus |
Max tube voltage | 80kV | |
Max tube current | 600μA | |
30μm | ||
Flat panel detector | Type | Super definition digital FPD |
Effective area | 430mm*430mm | |
Pixel size | 139μm | |
Resolution | 3072*3072 | |
Reel/tray counting | Max size | 17” (430mm) |
Max thickness | 88mm | |
Min parts size | 01005 | |
Speed | ≤10s | |
Accuracy | 01005 ≥ 99.98%, 0201 & above ≥ 99.99% | |
Equipment | Dimensions | 1000mm (L) * 1300mm (W) * 1820mm (H) |
Weight | 650kg | |
Power supply | AC110-220V 50/60HZ | |
Max power | 800W | |
Industrial PC | I7 CPU, 16G RAM, 256G SSD+4T HDD | |
Displayer | 24” HDMI LCD | |
Other functions | Auto code scanning | Barcode and QR code. |
Label printing | print the corresponding label when user takes out a reel. | |
Counting record | Inquiry by time range, work order number. | |
Management system connection | MES, ERP, WMS etc. | |
Mode switching | No need to switch single/multi reel mode | |
Work order no. | Support work order number recording | |
Safety | Radiation leakage | No leakage, international standard: ≤1μSv/h. |
Back door safety interlock | Once users open the back door, X-ray tube will power off immediately. When the back door is open, users can’t turn on the X-ray. | |
Anti-pinch | Safety light curtain covers the whole drawer, the drawer will stop immediately when something enters. | |
Emergency stop | In front of the operation position, press to power off. |
Working Principle
Application
Automaticlly counting resistors, capacitors, inductors, crystals, LED, diodes, transistors, and other multi-pin IC.
Radiation Safety Guarantee
All X-ray machines manufactured by Wellman meet the requirement of FDA-CDRH Regulation CFR 21 1020.40 Subchapter J for cabinet x-ray systems. The FDA – CDRH standard for cabinet x-ray systems states that radiation emission shall not more than. 5millirem a /hr.2″from any external surface. Our machines (X-Ray Radiation Level <1μSv/h ) are typically 5-10 times less emission than the standards, so there are no radiation concerns for operators.
Operation Safety | |
---|---|
Radiation Leakage | No leakage, international standard: ≤1μSv/h |
Lead Glass Observation Window | Transparent lead glass window to shields radiation, safe to observe the inner status. |
Window and Back Door Safety Interlock | Once open the window or back door, the X-ray tube will power off immediately. When the window or back door is open, the operator cannot turn on the X-ray. |
Electromagnetic Safety Switch | Once the X-ray is on, the window will automatically lock, so the operator can’t open the window. |