G-511 Series Sealed Microfocus X-Ray Source
The G-511 Series Sealed Transmissive Microfocus X-Ray Source is a high-performance industrial imaging solution designed for non-destructive inspection applications. It offers high clarity and resolution, with a minimum resolution of 2μm at 6W, making it suitable for detailed imaging in industries such as electronics, automotive, and aerospace. This compact and efficient device enhances imaging efficiency and precision, ensuring reliable and accurate results.
Key Features:
- Achieves a minimum resolution of 2μm at 6W for detailed imaging.
- High magnification with a focal spot size of 0.29mm.
- Wide X-ray radiation angle of 168° for comprehensive coverage.
- Rapid voltage increase to 110kV in under 1 second for quicker imaging.
- Self-diagnostic functionality for X-ray tube lifespan, ensuring planned maintenance.
- Preheat time of less than 3 minutes for immediate use after startup.
- Compliance with CE and RoHS standards for international usability.
- Continuous and pulse operation modes (≥1sec) for versatile imaging needs.
Technical Datasheet:
Mechanical Specifications:
Mechanical Specifications:
- Dimensions: 270 mm (L) x 150 mm (W) x 110 mm (H)
- Weight: 21 kg (G-511VL-D), 24 kg (G-511VL-DL)
- Installation Surfaces: Top (ray exit side) and bottom
- Mounting: 4 x M5, Depth 10, 8 x M5, Depth 5
Electrical Specifications:
- Maximum Power Consumption: 53W
- Input Voltage: DC 24V (+1.2, -1.2)
- Tube Voltage Operational Range: 40-110kV
- Tube Current Operational Range: 10-100μA
- Maximum Output: 20W
Environmental Specifications:
- Operating Temperature: 10°C to 45°C
- Storage Temperature: 0°C to 50°C
- Humidity: ≤85% RH (non-condensing)
X-ray Specifications:
- X-ray Beam Angle: 168° (maximum), 80° (80%, equidistant)
- X-ray Window Material/Thickness: C (Diamond) / 0.29mm
- Target Material: W (Tungsten)
- X-ray Dose Uniformity: Refer to graph (Page 1)
Control Specifications:
- Operation Mode: Continuous, Pulse (≥1sec)
- External Control: RS-232C
Safety and Handling Specifications:
- High Voltage Power Supply: Built-in
- Interlocks: 2 (INTERLOCK1, INTERLOCK2)
- Cooling Method: Forced Convection